50 stillman road, north haven ct 06473 call 800-243-2000 or 203-239-2090
Pulse opaque firing Guide
Press Correction:
To make corrections on the pressed objects, use the ceramic powders i1-i5 designated for this purpose. The necessary firing parameters are depicted in the table below.
| Start Temp | Closing Time | Vacuum Start | Temp increase in °C/ min. | Final Temp | Holding Time | Cooling Time | |
| Press Correcture | 400°C | 4 min. | 400°C | 45 | 880°C | 1 min. | 1 min. |
| Stains | 400°C | 4 min. | 400°C | 45 | 740°C | 1 min. | 1 min. |
| Glaze | 400°C | 4 min. | 400°C | 45 | 720°C | 1 min. | 1 min. |